Technical Data
This in formation is
for the following appliances:
Belling Hobs GHU60/70 front & side
control - NG & LPG
Data badge Underside of the hob
base
Electrical supply
240V ~ 50Hz 1W
Ignition
Mains repetitive ignition.
Gas connectionThe inlet connection
is at the rear right-hand side -
ISO7 - Rp1/2” (1/2” BSP)
Gas pressure settings
Natural gas @ 1.0kPa
Propane gas @ 2.75kPa
Countries of destination
(AUS & NZ)
26.4
Injector
6.50
Total Heat Input
82Front RH
6.50
87
MJ/h
87
6.50
50
Wok
70
6.50
118
50
118
Front LH
6.50
Back RH
Burner
10.20
12.60
6.50
9.50
3.20
MJ/h
Back RH
25.70
138-72
GHU 60
Front RH
Natural Gas
12.60
39.0
GHU 70
GHU 70
118
142
3.20 3.20
9.50
LP Gas
118
6.50
Back LH
82
GHU 60
3.20
70
Front LH
Back LH
70
Injector
38.30
87-35
14210.20
6.50
70