installation
Clearances and dimensions – re-
quirements
1. No shelf or overhang of combustible
material should be closer than 650mm
above the hob.
2. There must be a minimum clearance
of 50mm between the edges of the hob
and any side walls; this clearance must
be maintained up to 420mm above the
worktop.
3. There must be a minimum clearance of
50mm between the rear edge of the hob
and the rear wall. This clearance must
be maintained up to 650mm above the
worktop.
4. When installing an extractor hood
above the hob, refer to their Manufac-
turer’s instructions.