Installation InstructionsChimney-Style HoodsIndoor and Outdoor ApplicationsIMPORTANT SAFETY INSTRUCTIONSPLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCE
The following instructions only apply when installing a CFM-600C in a 30" Chimney hood.The Independent 30" Chimney hood has an adapter plate
If using a remote fan with the Chimney hood, follow the instructions listed below.The Independent Chimney hood is designed for 3 speed fan motors only
321HALOGENLIGHTHALOGENLIGHT6-PINCONNECTORFANSWITCHHI-HEATTHERMOSTATNL16-PINCONNECTORSEE DETAILGTERMINAL BLOCKHALOGENLIGHTINTERNALBLOWERCFM600 ORCFM120
IN-HOOD & REMOTE FANSMaximum CFM: 600Electrical Motor Rating:3.8 Amps @ 115V AC, 60 HzDuct Size at Discharge:3-1/4" X 16-3/4" X 8"
14USE AND CARECONTROLSAlways turn the hood on before cooking to establish anair flow in the kitchen. Allow the fan to operate for afew minutes to clea
CLEANING RECOMMENDATIONSBRUSHED STAINLESS STEEL, HAMMERED STAINLESS, EUROPEAN BLACK STEEL, 1920’sANTIQUATED TIN, MILLENNIUM DISK STAINLESSThe Brushed
191 Coney Island Drive • Sparks, NV 89431800-763-8232ULC®FILE # 204107UL®Independent Inc. reserves the right to change specifications or design withou
CAUTION -TO REDUCE THE RISK OF FIRE,ELECTRIC SHOCK, OR INJURY TOPERSONS, OBSERVE THEFOLLOWING:CAUTION: FOR GENERALVENTILATION USE ONLY. DO NOTUSE TO
MODEL OPTIONSModel Lights Fans Material CHIMNEY - CHIM 30" 2 CFM600C Stainless Steel CHIMNEY - CHIM 36" 2 CFM600C, CFM1200C, CFMR1400 Sta
THE CHIMNEY HOOD COMES WITH AN INSTALLATION PACKAGEWHICH INCLUDES THE FOLLOWING ITEMS1. Ten (10) 10/24 Nuts2. Ten (10) #10 Self Tapping Screws 2"
2. ROUGH-IN DIMENSIONS OF HOOD ASSEMBLY5Figure 3.Electrical and DuctworkRough-In locationTop ViewFigure 15.30" Chimney Hood includes8" Round
1. Position the Chimney hood on its back and locate the transition inside the Chimney hood; remove the (4) #8x 1/2" self tapping screws at the
78. Electrician may complete electrical connection to Hood making the connection at the box inside the hood. (120 volt) See Figure (2) If using a rem
8ALTERNATE INSTALLATION: CHIMNEY HOODUnder certain circumstances the installer may opt for a differentinstallation sequence. The alternate sequence is
USING A CHIMNEY HOOD IN A REAR DISCHARGE APPLICATIONThe Independent Chimney Hood can adapt to a rear discharge application with the following limitati