Installation Instructions
Chimney-Style Hoods
Indoor and Outdoor Applications
IMPORTANT SAFETY INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT:
INSTALLER:
OWNER:
SAFETY WARNING:
Save these instructions for the Local Electrical Inspector’s use.
Please leave these instructions with this unit for the owner.
Please retain these instructions for future reference.
Turn off power circuit at the service panel and lock out panel,
before wiring this unit.
CAUTION - TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
1. Use this unit only in the manner
intended by the manufacturer. If you
have any questions, contact the
manufacturer - Independent Inc.
(800-7-NEVADA)
2. Before servicing or cleaning the unit,
switch power off at service panel and
lock the service disconnecting means to
prevent power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
attach a tag to the service panel to
indicate power has been switched off
for maintenance.
3. Install this Rangehood Only with
Remote Blower Models Rated
Maximum 12.8A or Integral Blowers
manufactured by Independent Inc.,
Models CFM 600, CFM600C,
CFM1200, CFM1200C.
CAUTION: FOR GENERAL
VENTILATION USE ONLY. DO NOT
USE TO EXHAUST HAZARDOUS OR
EXPLOSIVE MATERIALS OR VAPOR.
2. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately.
EVACUATE AND CALL THE FIRE
DEPARTMENT.
3. NEVER PICK UP A FLAMING PAN
- you may be burned.
4. DO NOT USE WATER, including wet
dish-cloths or towels - a violent steam
explosion will result.
5. Use an extinguisher ONLY if:
a.You know you have a class ABC
extinguisher, and you already know
how to operate it.
b.The fire is small and contained in
the area where it started.
c. The fire department is being called.
d.You can fight the fire with your back
to an exit.
CAUTION - TO REDUCE THE RISK
OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended
at high settings.
Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at
high heat or when flambeing foods
(i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe.
3. Clean ventilating fans frequently.
Grease should not be allowed to
accumulate on fan or filter.
4. Always use cookware appropriate for the
size of the surface element.
CAUTION - TO REDUCE THE RISK
OF INJURY TO PERSONS, IN THE
EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:
1. SMOTHER FLAMES with a close-
fitting lid, cookie sheet, or other metal
tray, then turn off the gas burner or the
electric element.
1
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Chimney-Style Hoods

Installation InstructionsChimney-Style HoodsIndoor and Outdoor ApplicationsIMPORTANT SAFETY INSTRUCTIONSPLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCE

Page 2 - INSTALLATION PRECAUTIONS

The following instructions only apply when installing a CFM-600C in a 30" Chimney hood.The Independent 30" Chimney hood has an adapter plate

Page 3 - MODEL OPTIONS

If using a remote fan with the Chimney hood, follow the instructions listed below.The Independent Chimney hood is designed for 3 speed fan motors only

Page 4 - STEP 1. DUCTING CONNECTION

321HALOGENLIGHTHALOGENLIGHT6-PINCONNECTORFANSWITCHHI-HEATTHERMOSTATNL16-PINCONNECTORSEE DETAILGTERMINAL BLOCKHALOGENLIGHTINTERNALBLOWERCFM600 ORCFM120

Page 5 - Figure 4

IN-HOOD & REMOTE FANSMaximum CFM: 600Electrical Motor Rating:3.8 Amps @ 115V AC, 60 HzDuct Size at Discharge:3-1/4" X 16-3/4" X 8"

Page 6

14USE AND CARECONTROLSAlways turn the hood on before cooking to establish anair flow in the kitchen. Allow the fan to operate for afew minutes to clea

Page 7 - Figure 7

CLEANING RECOMMENDATIONSBRUSHED STAINLESS STEEL, HAMMERED STAINLESS, EUROPEAN BLACK STEEL, 1920’sANTIQUATED TIN, MILLENNIUM DISK STAINLESSThe Brushed

Page 8

191 Coney Island Drive • Sparks, NV 89431800-763-8232ULC®FILE # 204107UL®Independent Inc. reserves the right to change specifications or design withou

Page 9

CAUTION -TO REDUCE THE RISK OF FIRE,ELECTRIC SHOCK, OR INJURY TOPERSONS, OBSERVE THEFOLLOWING:CAUTION: FOR GENERALVENTILATION USE ONLY. DO NOTUSE TO

Page 10

MODEL OPTIONSModel Lights Fans Material CHIMNEY - CHIM 30" 2 CFM600C Stainless Steel CHIMNEY - CHIM 36" 2 CFM600C, CFM1200C, CFMR1400 Sta

Page 11 - HIGH HEAT SENSOR

THE CHIMNEY HOOD COMES WITH AN INSTALLATION PACKAGEWHICH INCLUDES THE FOLLOWING ITEMS1. Ten (10) 10/24 Nuts2. Ten (10) #10 Self Tapping Screws 2"

Page 12 - NO < 200F

2. ROUGH-IN DIMENSIONS OF HOOD ASSEMBLY5Figure 3.Electrical and DuctworkRough-In locationTop ViewFigure 15.30" Chimney Hood includes8" Round

Page 13

1. Position the Chimney hood on its back and locate the transition inside the Chimney hood; remove the (4) #8x 1/2" self tapping screws at the

Page 14 - USE AND CARE

78. Electrician may complete electrical connection to Hood making the connection at the box inside the hood. (120 volt) See Figure (2) If using a rem

Page 15 - CLEANING RECOMMENDATIONS

8ALTERNATE INSTALLATION: CHIMNEY HOODUnder certain circumstances the installer may opt for a differentinstallation sequence. The alternate sequence is

Page 16 - TROUBLESHOOTING TIPS

USING A CHIMNEY HOOD IN A REAR DISCHARGE APPLICATIONThe Independent Chimney Hood can adapt to a rear discharge application with the following limitati